2.7. Testing and Debugging a PMDA

Ensuring the correct operation of a PMDA can be difficult, because the responsibility of providing metrics to the requesting PMCD process and simultaneously retrieving values from the target domain requires nearly real-time communication with two modules beyond the PMDA's control. Some tools are available to assist in this important task.

2.7.1. Overview

Thoroughly testing a PMDA with PMCD is difficult, although testing a daemon PMDA is marginally simpler than testing a DSO PMDA. If a DSO PMDA exits, PMCD also exits because they share a single address space and control thread.
The difficulty in using PMCD to test a daemon PMDA results from PMCD requiring timely replies from the PMDA in response to request PDUs. Although a timeout period can be set in ${PCP_PMCDOPTIONS_PATH}, attaching a debugger (such as gdb) to the PMDA process might cause an already running PMCD to close its connection with the PMDA. If timeouts are disabled, PMCD could wait forever to connect with the PMDA.
If you suspect a PMDA has been terminated due to a timeout failure, check the PMCD log file, usually ${PCP_LOG_DIR}/pmcd/pmcd.log.
A more robust way of testing a PMDA is to use the dbpmda tool, which is similar to PMCD except that dbpmda provides complete control over the PDUs that are sent to the PMDA, and there are no time limits--it is essentially an interactive debugger for exercising a PMDA. See the dbpmda(3) man page for details.
In addition, careful use of PCP debugging flags can produce useful information concerning a PMDA's behavior; see the PMAPI(3) and pmdbg(1) man pages for a discussion of the PCP debugging and tracing framework.